- Water Filtering
- Water Filter Cartridges
- Anti limescale & Decalcifying
- Drinking bottles
- Water swirler
- Brands
- Sale %
- Accessory & Spare Parts
- Blog
WatPass® KombiGo Manganese, iron, softening
€2,199.00
Available, delivery time: 1-3 days
Product information "WatPass® KombiGo Manganese, iron, softening"
Product information "WatPass® KombiGo Manganese, Iron, Softening"
The WatPass® KombiGo removes manganese and iron from your well water and at the same time the water is softened.
NEW - Clack control head with German menu and color display. The color modes of the display make it easier to check the operating status (blue = everything is OK). If there is an error (red = malfunction), you can see it at a glance. The German menu makes setting up the system a lot easier. Other menu languages ??are EN, FR, ES and Polish.
The system is almost maintenance-free. All that is needed is to refill the additional container with salt every 3-4 months to regenerate the filter material. Its performance * is outstanding, it can filter up to 10.0 mg / l iron and 2.0 mg / l manganese from the water. In addition, the water is also softened. The installation of the system is very easy. The system is automatically regenerated in a quantity-controlled manner and the backwash water is disposed of through an outlet.
The system consists of a GRP pressure bottle (size is adapted to the performance), which is filled with high-quality filter material, as well as a salt storage container that is required to regenerate the filter material. A quantity-controlled central control valve, of the type Clack WS 1 CI IA, is currently the ultimate in the field of control valves for such systems. An additional mounting block (bypass) that can be purchased is used for bridging, but is not absolutely necessary for operation, but highly recommended.
How the special filter material works
The system can filter iron and manganese from your well water in one pass and soften the water at the same time. The filter material is a combination of adsorbers and ion exchange resins. The substances retained in the filter bed are then removed from the device during the backwashing process. It is seldom found in this form.
In order to be able to filter manganese and iron successfully, the WatPass KombiGo needs a pH value of at least 5.5 and max. 9.0. Normally, the pH value for the FE and Mn filtration must be significantly higher than with this innovative system.
Areas of application: Well water, garden irrigation, laundries, industrial water use, koi and fish ponds and all areas where too high a manganese and iron content in the water causes problems
The WatPass KombiGo is available in different versions depending on the performance requirements or the amount of well water to be treated (the color of the pressure bottle may differ in some versions). You can find this in the selection menu.
Further information on dimensions and technical data can be found below in the download area.
Depending on the spatial conditions and the equipment requirements, we recommend that you consider purchasing the following accessories:
Connection set 1 inch depending on the system size
2x armored hose 1 inch collar x 1 inch collar, L = 1,000 mm; 1x drainage hose, L = 2,000mm;
1x hose clamp 1/2 inch; 4x seals; 1x overflow hose, L = 2,000mm
Connection set 1 1/4 inches depending on the system size
2x armored hose 1 1/4 inch collar x 1 1/4 inch collar, L = 1,000 mm; 1x drain hose,
L = 2,000mm; 1x hose clamp 1/2 inch; 1x overflow hose; L = 2,000mm; 4x seals
Mounting block 1 inch IT x 1 inch AG
with intersection, bypass function, sampling tap
Installation information for connection to public networks: If the KombiGo filter systems are to be used in the drinking water area, they must comply with the "Rules for drinking water installations" according to DIN 1988-200 in conjunction with DIN EN 1717: 2011-08. Then it is necessary to install a pipe separator to protect the public drinking water network. Necessary installation conditions: water connection, socket 230 V / 50 Hz, waste water connection, pressure reducer at> 6 bar
Transport and costs: The article is delivered by a forwarding agent to avoid transport damage.
* The specified filter performance are the maximum achievable values ??under precisely analyzed conditions. A water analysis and determination of what the water should be used for is a basic requirement for good advice and the selection of the right filter system. Well water can be subject to fluctuations in its composition due to various environmental influences. A regular analysis should therefore take place in order to be able to adapt the filter devices, e.g. B. the regeneration cycle is changed.
Ladenkiste UG (haftungsbeschränkt)
Bahnhofstr.
34286
Spangenberg
Deutschland
kontakt@wasserfilter-zentrum.de
Similar items
If, as a well operator, you have low pH levels in your water and you want to use it as drinking water, the WatPass® pHGo offers you an excellent opportunity to increase the ph value in order to comply with the regulations of the Drinking Water Ordinance (pH 6.5-9, 5, TrinkwVo 2001/11). The system consists of a GRP pressure bottle, which is filled with a material for pH increase. A volume-controlled central control valve, type Clack WS 1 CI, currently represents the ultimate in control valves for such systems. Background Acidic water is corrosive. As the pH drops, the proportion of free carbonic acid increases, attacking all metals except stainless steel. This leads to leaks in the water installation over time. It also pollutes your drinking water with copper, zinc or aluminum. The WatPass pHGo contains a mineral that neutralizes the excess carbonic acid and immediately increases the pH value. The mineral is a consumable and must be refilled 1-3 times a year, depending on local conditions. Installation Behind the well pump or in front of the pressure vessel, if available. To ensure proper backwash, a pressure control must be installed in front of the neutralizer or a bypass of the existing pressure switch to allow the well pump to start delivering water when the neutralizer backwash valve is opened. Recommendation: To maintain the performance and service life of the device, a sediment filter should be installed. If the iron and manganese contents of your well water are too high and you want to use the WatPass IronGo, but the pH value is too low for the proper functioning of the device, then the WatPass phGo is the solution for this case! The WatPass phGo raises the pH of your well water to a level that allows the WatPass IronGo to be used for iron removal, even if the pH of your water is below 6.8. The installation is serial, before the WatPass IronGo and is very simple. Depending on the desired performance or the amount of well water to be treated, the WatPass phGo is also available in other versions. If the model offered by us does not fit, of course we can also sell you another, suitable device. Just ask us! Applications Well water, garden irrigation, laundries, hot water, koi and fish ponds and all areas where too low ph value of your water prevents iron ironing with the IronGo. Depending on the spatial conditions and equipment requirements, we recommend that you consider the purchase of the following accessories: Connection set 1 inch depending on system size 2x armored hose 1 inch ÜM x 1 inch ÜM, L = 1.000 mm; 1x drain hose, L = 2,000mm; 1x hose clamp 1/2 inch; 4x seals; 1x overflow hose, L = 2.000mm Connection set 1 1/4 inch depending on system size 2x armored hose 1 1/4 inch ÜM x 1 1/4 inch ÜM, L = 1.000 mm; 1x drain hose, L = 2,000mm; 1x hose clamp 1/2 inch; 1x overflow hose; L = 2.000mm; 4x seals Mounting block 1 inch IG x 1 inch AG with intersection, bypass function, sampling tap Note: A water analysis and determination of what the water should be used for is a prerequisite for good advice and the selection of the right filter system. Well water may be subject to variations in composition due to various environmental influences. Therefore, a regular analysis should take place to be able to adapt the filter devices by For example, the regeneration cycle is changed. Installation instructions for connection to public networks: If the WP ManganGo filter systems are to be used in the drinking water sector, they must comply with the "Rules for drinking water installations" according to DIN 1988 -200 in conjunction with DIN EN 1717: 2011-08. Then it is necessary to install a backflow preventer to protect the public drinking water network. Necessary installation conditions: Water connection socket 230 V / 50 Hz, waste water connection, pressure reducer at> 6 bar Transport and costs: The item is delivered to avoid transport damage by freight carrier.
The connection set is suitable for the ironing machines WatPass IronGo (EV-B1 and EW-B1) and manganese removal systems such as WatPass ManganGo (3.3m³ / h and 4.4m³ / h) or just as it is needed. Delivery The connection set 1 1/4 inch contains: 2x armored hose DVGW 1 1/4" ÜM x 1 1/4 "ÜM, L = 1.000 mm; 1x drain hose, L = 2.000mm; 1x hose clamp 1/2"; 1x overflow hose; L = 2.000mm; 4x seals
The assembly block is suitable for the AquaAvanti IronGo iron filter and manganese filter AquaAvanti ManganGo or where a bypass is needed. If there is limited space at the point of connection, the use of a mounting block is ideal. For safety reasons, it may be desirable to be able to bridge the device unit. For such cases, the mounting block (bypass) is ideal. The installation of a mounting block usually takes about one hour. Your installer will surely make you an offer. If you are not sure if you need a mounting block just ask him. The mounting block is working that way Position 1 When the two outer taps are closed and the middle tap is open, the water flows past the connected device (eg AquaAvanti Iron GO or AquaAvanti ManganGo). Position 2 If the two outer cocks are open and the middle closed, all the water flows through the connected devices. Note: If it is necessary to bridge the units, simply return the mounting block to position 1.
The connection set is suitable for the disinfestation systems AquaAvanti IronGo (except EV-B1 and EW-B1) and equipment for manganese removal such as AquaAvanti ManganGo (except models with 3,3m³/h and 4,4m³/h flowrate) or just as it is needed. Delivery The connection set 1 inch contains: 2x armored hose DVGW 1 "ÜMxÜM, L-1.000mm, drain hose and overflow hose each 1.500mm, 1/2" hose clamp, 4 gaskets